Click to download the details of ASME SA213 TP304L Seamless Stainless Steel Tubes.
ASME SA213 TP304/TP304L Seamless stainless tubes is for heat exchangers.
ASME SA213 Covers seamless ferritic and austenitic steel boiler, superheater, and heat-exchanger tubes.
ASME SA213 Stainless Steel tubes Grades TP304, TP304L, TP304H, TP309S, TP309H, TP310S, TP310H, TP316, TP316L, TP316H, TP317, TP317L, TP321, TP321H, TP347, TP347H, TP348, TP348H, TP444…
ASME SA213 tubes shall be made by the seamless process and shall be either hot-finished or cold finished as specified.
Description Name: ASTM A213 seamless stainless tubes, ASTM A213 stainless pipes, A312 seamless stainless tubes, TP304/TP304L/TP304H stainless tubes, TP309S/TP309H stainless tubes, TP310S/TP310H stainless tubes, TP316/TP316L stainless tubes. TP321/TP321H stainless tubes, TP347/TP347H stainless tubes, seamless stainless tubes, stainless tubes
Size: 1/8” to 24” (10.3mm to 610mm)
Schedules: 10s, 20, 40s, 40, 60, 80s, 80, 100, 120, 140, 160, XXH
Wall Thickness: 1mm to 60mm
| Grade | Specification |
| Stainless 304/304L, 304/304H | ASTM A213/SA213 |
| Stainless 309S | ASTM A213/SA213 |
| Stainless 310S | ASTM A213/SA213 |
| Stainless 316/316L, 316/316H | ASTM A213/SA213 |
| Stainless 317/317L | ASTM A213/SA213 |
| Stainless 321/321H | ASTM A213/SA213 |
| Stainless 347/347H | ASTM A213/SA213 |
Shape: Round
Length: Single random length/ Double random length or as customer’s actual request
Max length 25000mm
Referenced Documents:
ASTM Referenced Standards
A 262 Practices for Detecting Susceptibility to Intergranu- lar Attack in Austenitic Stainless Steels
A 941 Terminology Relating to Steel, Stainless Steel, Re- lated Alloys, and Ferroalloys
A 1016/A 1016M Specification for General Requirements for Ferritic Alloy Steel, Austenitic Alloy Steel, and Stain- less Steel Tubes
E 112 Test Methods for Determining Average Grain Size
Chemical Composition:
| Grade | UNS Design | Composition, % | ||||||||||||||
| C | Mn | P | S | Si | Cr | Ni | Mb | Ti | Nb | N | Cu | Ce | B | Al | ||
| TP304 | S30400 | 0.08 | 2 | 0.045 | 0.03 | 1 | 18.0–20 | 8.0–11 | . . . | . . . | . . . | . . . | . . . | . . . | ||
| TP304L | S30403 | 0.035 | 2 | 0.045 | 0.03 | 1 | 18.0–20 | 8.0–13 | . . . | . . . | . . . | . . . | . . . | . . . | ||
| TP304H | S30409 | 0.04 – 0.1 | 2 | 0.045 | 0.03 | 1 | 18.0–20 | 8.0–11 | . . . | . . . | . . . | . . . | . . . | . . . | ||
| TP310S | S31008 | 0.08 | 2 | 0.045 | 0.03 | 1 | 24.0- 26 | 19.0- 22 | 0.8 | . . . | . . . | . . . | . . . | . . . | ||
| TP310H | S31009 | 0.04 – 0.1 | 2 | 0.045 | 0.03 | 1 | 24.0–26 | 19.0–22 | . . . | . . . | . . . | . . . | . . . | |||
| TP310H | S31035 | 0.04 – 0.1 | 0.6 | 0.025 | 0.015 | 0.4 | 21.5–23.5 | 23.5–26.5 | . . . | . . . | 0.40- 0.6 | 0.20- 0.3 | 2.5- 3.5 | . . . | 0.002- 0.008 | |
| TP316 | S31600 | 0.08 | 2 | 0.045 | 0.03 | 1 | 16.0–18 | 10.0–14 | 2.00–3 | . . . | . . . | . . . | . . . | . . . | ||
| TP316L | S31603 | 0.035 | 2 | 0.045 | 0.03 | 1 | 16.0–18 | 10.0–14 | 2.00–3 | . . . | . . . | . . . | . . . | . . . | ||
| TP316H | S31609 | 0.04 – 0.1 | 2 | 0.045 | 0.03 | 1 | 16.0–18 | 10.0–14 | 2.00–3 | . . . | . . . | . . . | . . . | . . . | ||
| TP317 | S31700 | 0.08 | 2 | 0.045 | 0.03 | 1 | 18.0–20 | 11.0–15 | 3.0–4 | . . . | . . . | . . . | . . . | . . . | ||
| TP317L | S31703 | 0.035 | 2 | 0.045 | 0.03 | 1 | 18.0–20 | 11.0–15 | 3.0–4 | . . . | . . . | . . . | . . . | . . . | ||
| TP321 | S32100 | 0.08 | 2 | 0.045 | 0.03 | 1 | 17.0–19 | 9.0–12 | . . . | Ti 5 × (C+N) min, 0.70 max | . . . | 0.1 | . . . | . . . | ||
| TP321H | S32109 | 0.04 – 0.1 | 2 | 0.045 | 0.03 | 1 | 17.0–19 | 9.0–12 | . . . | 4(C+N) min; 0.70 max | . . . | 0.1 | . . . | . . . | ||
| TP321H | S32654 | 0.02 | 2.0-4 | 0.03 | 0.005 | 0.5 | 24.0–25 | 21.0–23 | 7.0-8 | . . . | . . . | 0.45- 0.55 | 0.30-0.6 | . . . | ||
| TP321H | S33228 | 0.04 – 0.08 | 1 | 0.02 | 0.015 | 0.3 | 26.0–28 | 31.0–33 | . . . | . . . | 0.60- 1 | . . . | . . . | 0.05 – 0.1 | 0.025 | |
| TP321H | S34565 | 0.03 | 5.0-7 | 0.03 | 0.01 | 1 | 23.0–25 | 16.0–18 | 4.0-5 | . . . | 0.1 | 0.40- 0.6 | . . . | . . . | ||
| TP347 | S34700 | 0.08 | 2 | 0.045 | 0.03 | 1 | 17.0–19 | 9.0–13 | . . . | . . . | See Spec | . . . | . . . | . . . | ||
| TP347H | S34709 | 0.04 – 0.1 | 2 | 0.045 | 0.03 | 1 | 17.0–19 | 9.0–13 | . . . | . . . | See Spec | . . . | . . . | . . . | ||
| TP348 | S34800 | 0.08 | 2 | 0.045 | 0.030 | 1 | 17.0–19 | 9.0–13 | . . . | . . . | . . . | . . . | . . . | . . . | Co 0.20, Ta 0.10 | |
| TP348H | S34809 | 0.04-0.10 | 2 | 0.045 | 0.030 | 1 | 17.0–19.0 | 9.0–13 | . . . | . . . | . . . | . . . | . . . | . . . | . . . | Co 0.20, Ta 0.10 |
| TP444 | S44400 | 0.03 | 1.0 | 0.040 | 0.030 | 1 | 17.5–19.5 | . . . | 1.75-2.50 | 0.035 | . . . | . . . | . . . | . . . | . . . | . . . |
Heat Treatment Requirements
| Grade | UNS Designation | Heat Treat Type | Austenitizing/ Solutioning Temperature, min or range °F [°C] | Cooling Media | ASTM Grain Size No. B |
| TP304 | S30400 | Solution treatment | 1900 °F [1040 °C] | water or another rapid cool | . . . |
| TP304L | S30403 | Solution treatment | 1900 °F [1040 °C] | water or another rapid cool | . . . |
| TP304H | S30409 | Solution treatment | 1900 °F [1040 °C] | water or another rapid cool | 7 |
| TP309S | S30908 | Solution treatment | 1900 °F [1040 °C] | water or another rapid cool | . . . |
| TP309H | S30909 | Solution treatment | 1900 °F [1040 °C] | water or another rapid cool | 7 |
| TP310S | S31008 | Solution treatment | 1900 °F [1040 °C] | water or another rapid cool | . . . |
| TP310H | S31009 | Solution treatment | 1900 °F [1040 °C] | water or another rapid cool | 7 |
| TP316 | S31600 | Solution treatment | 1900 °F [1040 °C] | water or another rapid cool | . . . |
| TP316L | S31603 | Solution treatment | 1900 °F [1040 °C] | water or another rapid cool | . . . |
| TP316H | S31609 | Solution treatment | 1900 °F [1040 °C] | water or another rapid cool | 7 |
| TP317 | S31700 | Solution treatment | 1900 °F [1040 °C] | water or another rapid cool | . . . |
| TP317L | S31703 | Solution treatment | 1900 °F [1040 °C] | water or another rapid cool | . . . |
| TP321 | S32100 | Solution treatment | 1900 °F [1040 °C] | water or another rapid cool | . . . |
| TP321H | S32109 | Solution treatment | cold worked:2000[1090] hot rolled: 1925 [1050]H | water or another rapid cool | 7 |
| TP347 | S34700 | Solution treatment | 1900 °F [1040 °C] | water or another rapid cool | . . . |
| TP347H | S34709 | Solution treatment | cold worked:2000[1100] hot rolled: 1925 [1050]H | water or another rapid cool | 7 |
| TP444 | S44400 | subcritical anneal | . . . | . . . | . . . |
Tensile Requirements
| Grade | UNS | Tensile Strength, Min ksi [MPa] | Yield strength, min ksi [MPa] | Elongation in 2 in. or 50 mm, min, %A, B | Hardness, Max | |
| Designation | Brinell/Vickers | Rockwell | ||||
| TP304 | S30400 | 75 [515] | 30 [205] | 35 | 192HBW/200Hv | 90HB |
| TP304L | S30403 | 70 [485] | 25 [170] | 35 | 192HBW/200Hv | 90HB |
| TP304H | S30409 | 75 [515] | 30 [205] | 35 | 192HBW/200Hv | 90HB |
| TP304N | S30415 | 80 [550] | 35 [240] | 35 | 192HBW/200Hv | 90HB |
| TP310S | S31008 | 75 [515] | 30 [205] | 35 | 192HBW/200Hv | 90HB |
| TP310H | S31009 | 75 [515] | 30 [205] | 35 | 192HBW/200Hv | 90HB |
| TP316 | S31600 | 75 [515] | 30 [205] | 35 | 192HBW/200Hv | 90HB |
| TP316L | S31603 | 70 [485] | 25 [170] | 35 | 192HBW/200Hv | 90HB |
| TP316H | S31609 | 75 [515] | 30 [205] | 35 | 192HBW/200Hv | 90HB |
| TP316Ti | S31635 | 75 [515] | 30 [205] | 35 | 192HBW/200Hv | 90HB |
| TP317 | S31700 | 75 [515] | 30 [205] | 34 | 192HBW/200Hv | 90HB |
| TP317L | S31703 | 75 [515] | 30 [205] | 35 | 192HBW/200Hv | 90HB |
| TP321 | S32100 | 75 [515] | 30 [205] | 35 | 192HBW/200Hv | 90HB |
| TP321H | S32109 | 75 [515] | 30 [205] | 35 | 192HBW/200Hv | 90HB |
| TP347 | S34700 | 75 [515] | 30 [205] | 35 | 192HBW/200Hv | 90HB |
| TP347H | S34709 | 75 [515] | 30 [205] | 35 | 192HBW/200Hv | 90HB |
| TP444 | S44400 | 60 [415] | 40 [275] | 20 | 217 HBW/230HV | 96HB |
Flattening Test
One flattening test shall be made on specimens from each end of one finished tube, not the one used for the flaring test, from each lot.
Flaring Test
One flaring test shall be made on speci- mens from each end of one finished tube, not the one used for the flattening test, from each lot.
Hydrostatic or Nondestructive Testing
Each pipe shall be subjected to the nondestructive electric test or the hydrostatic test, the type of test to be used shall be at the option of the manufacturer, unless otherwise specified in the purchase order.
Markings
Markings will adhere to prescribed specifications in A999/A999M and shall include the NPS or OD and schedule number or average wall thickness, heat number, and NH (when hydrotesting is not performed) and ET (when eddy-current testing is performed) or UT (when ultrasonic testing is performed). The marking shall also include the manufacturer’s private identifying mark, the marking requirement of section 12.3 on Hydrostatic or Nondestructive Electric Test, if applicable, and whether seamless (SML), welded (WLD), or heavily cold-worked (HCW). For Grades TP304H, TP316H, TP321H & TP347H, the marking shall also include the heat number and heat-treatment lot identification.
Note:
- Mill test certificates will be issued according to EN10204.3
- All tubes shall be supplied as per applicable ASTM A213 /A213M Specification.